L Unproductive Dollars “ FIRE PREVENTION will make the most headway when it captures the individual and leads him to be careful in his own surroundings. Likewise fire protection will accomplish most when it is applied locally; the more direct and prompt the application at the start of the fire the better, and the smaller the loss.” Extract from an address by Henry O. Lacount , former President of the Na~ tional Fire Protection Association. Copyright 1927, Foamite-Childs Corporation, Utica, N.Y. AVERY LIBRARY COLL' .'.'.LI A UNIVERSIT- •T\ Suppose Tour Property Caught Fire? A SMALL BLAZE—a wisp of smoke! Instantly confusion — maybe panic, human lives crushed out, lives sacrificed need- l lessly. Soon a mass of roaring flames, billowing smoke.Then the alarm, the screech of fire sirens, the roar of racing motors, the hiss of pouring hose streams. Are you prepared for this and all that it entails? It may be your business property. Your business is suspended— your customers go elsewhere—your unfilled orders are cancelled—■ your income ceases while overhead continues. Or, it may be your home. Heirlooms and possessions it has taken a lifetime to accumulate gone in a day—objects precious beyond price which can never be replaced. And, the lives of those near and dear to you may be the final and crushing loss. Yes, the fire department helps to protect you. But, efficient as they may be, they are not infallible. Accidents may happen— congested traffic conditions, open bridges, train blockades are only a few of the handicaps that may delay them. Or, they may be at another fire. The first five minutes is the critical period in every fire —you cant afford to risk delays. The man who relies wholly on the fire department for protection is taking great chances. When someone discovers a way to tell when and where and to whom fire will come, then and only then can property owners neg¬ lect to have on hand adequate first-aid fire protection equipment. CO Is Your Business Menaced? F ire plays no favorites—it is a universal menace that threatens every man, every business. It reaches everywhere to take its claim in ruined property; to brand the stamp of failure on thou¬ sands of going concerns; to exact its toll in human lives. You may never have had a fire. But, tomorrow you may have one that will wipe out the business that it has taken years of hard work to build up. Every day $1,500,000 worth of property is burned up. Fire follows no schedule. It strikes blindly. Is there any reason why it cannot strike you? More Than Fire Insurance Is Needed T he vast business of fire insurance ranks today as one of the most fundamental factors in modern business life. Important business is conducted almost entirely by means of credit, and insurance is the foundation of the modern credit system. Fire insurance does away with the necessity of keeping capital idle, and also reduces to the lowest terms the paralyzing effect of conflagra¬ tions and distributes the burden of the loss throughout the country. As a matter of fact, it would be impossible to carry on business without insurance against loss by fire. But, more than fire insurance is needed, for fire destroys more than your property. Fire means loss to you, no matter how much fire insurance you carry. Think of the indirect losses that fire insurance alone cannot cover. Your journals, ledgers, papers, contracts, patent papers, leases, deeds, etc., the vital records of your business are lost in the blaze. Your production is stopped, patterns, tools, blue prints, jigs and fixtures are lost. Your income ceases. You lose the confidence and the business of old customers. You lose new business because your salesmen cannot make definite promises of delivery while your burned plant is being rebuilt. You lose your old reliable workers who are forced to find new jobs with other companies. These are but a few of the intangible but costly losses resulting from a serious fire that cannot be covered by fire insurance. Fire insurance can make good your property loss, but could you recover from such a business set-back? Especially, when one remembers that 30% of all industrial fires result in business failure? Such losses can be prevented, however, because fires can be killed before they cause serious damage. The installation of the correct type of first-aid fire-fighting equipment properly main¬ tained will minimize the many losses and inconveniences that invariably result from a fire. “Good Will” What Is It Worth to You? Y ou have been in business for years. People know about your product, your trade-mark, your company. You have built up good will—there is a demand for your product. Public opinion is a factor that often means either failure or success. You cannot afford to disregard the sentiments of the buying public, for it is on this that prosperity is built. To retain the public’s faith and favor, it is necessary to securely guard your good will. Fire can destroy good will. Fire may happen. Therefore, it is your duty to protect your plant so that fire can t happen to you. But, you should not lean entirely on the fire department or on fire insurance for your protection. You need more than a fire alarm box at your door. You need more than financial indemnity against fire disaster. You need protection adequate enough to make disaster impossible. Today, such protection is available. At relatively small cost you can install fire extinguishing equipment that will stifle any fire before it can do serious harm. But, that does not mean that anyone can go out and get real protection against fire by accepting what¬ ever may be offered as a “fire extinguisher.’’ It isn’t quite so sim¬ ple. It is necessary to know how fires and fire hazards differ, and how the several types of extinguishing devices apply to, or do not apply to, the particular hazards that are to be safeguarded. [ 3 ] Fires Are Not All Alike — Nor Are All Fire Extinguishers Ordinary Fire Risks— Wood .. Paper.. Rubbish Fires of ordinary combustibles can usually be put out with water, or with liquid chemicals discharged by certain types of extinguishers, but such fires can also be put out to better advan¬ tage by other than liquid chemi¬ cals. But there areother typesof fires where liquid extinguishing agents are worse than useless. Electrical Equipment- Motor Cars.. Small Motor Boats For these special fire hazards the most suitable first aid equip¬ ment is the Carbon Tetrachlo¬ ride type because it is compact and because its liquid is non¬ conducting and does not freeze above minus 50° Fahr. Extra-hazardous Fires— Oil.. Gasoline.. Paint .. Grease The only sure way to kill such fierce fires is by smothering them under Firefoam. Of course, Firejoam also kills ordinary fires—instantly, and with min¬ imum damage. After the fire is out,Firefoam dries and the dust which is left may be brushed or washed away. ask your fire chief or insurance agent how to put out an oil fire— l \ an electrical fire—an ordinary fire. His answer will show that a first-aid method effective on one kind of fire may prove useless on another kind. Which explains why so many fires gain destructive headway, interrupting business and causing losses that fire insur¬ ance can never repay. There are many different kinds of fires and for each of them there is an extinguisher which is the most effective. For the ordi¬ nary fire of wood and rubbish, almost any good extinguishing device, or even water alone, will usually bring results; but for the extra- hazardous fires, such as those of oils, greases, paints and other inflammable materials, the simple remedies will not suffice. Where there are unusual risks, special extinguishing devices should be provided which will be most effective against the particular haz¬ ards in question. Only the right type of fire extinguisher in the right place will give sure protection. Hundreds of unfortunate instances may be cited where people placed faith in extinguishing equipment that was not adequate for the property they supposedly safeguarded. Misapplication can be made with almost any type of fire extinguishing equipment; yet each type will put out fire under the particular conditions under which it can be effective. [ 4 ] You Can Make Sure of Getting the Right Extinguisher M odern fire extinguishing devices that are correctly designed to embody any one of the principles or methods perfected by the science of fire protection are “approved” and labeled by the Underwriters’ Laboratories, a national institution maintained by the National Board of Fire Underwriters for the examination and testing of appliances bearing on fire hazards. But it is highly important to know that there are several different kinds of Under¬ writers’ “approval,” for fire extinguishers, and that each one definitely indicates the type or class of fire for which the extin¬ guisher is effective. For all practical purposes, the Underwriters’ Laboratories have classified incipient fires into three general classes, known as Class “A,” Class “B,” and Class “C” fires. Briefly, Class “A” fires may be defined as incipient fires in ordinary combustible materials; Class “B” fires as those of inflammable liquids, greases, etc.; and Class “C” fires as those in electrical equipment. The Underwriters’ rating “A-i” on an extinguisher means that one such extinguisher is considered a unit of protection for Class “A” fires. The letter “A” signifies the class of fire against which the extinguisher is effective; the absence of the letters “B” and “C” is a warning that the device cannot be expected to give suit¬ able protection for Class “B” or Class “C” fires. The numeral “i” means that one such extinguisher makes a unit of protection. An “A-2” rating signifies that two such extinguishers are required to make up a unit of protection against Class “A” fires. Similarly the “B-2 C-2” ratings on an extinguisher mean that two such extin¬ guishers are necessary to make up a unit of protection for Class “B” or Class “C” fires—the absence of the letter “A” is a warning that the device cannot be expected to give suitable protection for Class “A” fires. The Chart Points the Way T he chart on pages 12 and 13 shows the comparative merit of each of the leading types of hand chemical fire extinguishers. It was compiled largely from information given in Underwriters’ official publications, and it is your guide to real fire protection. By consulting and following it, you can avoid the disasters which so often result from the purchase of extinguishing equipment which is inadequate for its purpose. [ 5 ] Such fires are generally big fires by the time the city fire department arrives—unless the owner of the plant has provided the proper first-aid devices for self-protection A Service to Help You Assure Effective Fire Protection T he surest and most satisfactory way to ascertain just what type of equipment will best protect your particular risks is to consult the Foamite organization. We offer, without charge, a complete engineering service to analyze your needs and make definite recommendations for the most effective means of securing protection for your particular property. We manufacture all standard types of chemical fire appliances, and can therefore speak with authority and without prejudice and recommend each device in its proper place and for its correct function. There is no longer any need for you to purchase any first-aid extinguishing device without knowing what it is and how it acts on different kinds of fires. If your house or business property is not adequately protected against fire, it will cost you nothing to have a Foamite specialist study your problem and tell you how you can secure the most effective protection against your peculiar risks. Foamite representatives are expert on all kinds of fires. Their practical experience covers the whole field of controlling fires sci¬ entifically. They can adapt exactly the right protection to the right place. At your request, they will survey your plant and prescribe the extinguishing agent that best safeguards your danger points. It will be worth your while to make sure. Send the post card, enclosed for your convenience, for this free advisory service. [ 6 ] This fire spread from a small beginning until, once beyond control, it had destroyed a great business property—prosperous and productive a few hours before this photograph was taken Four Points to Consider in Choosing Fire Extinguishing Devices I t is advisable to consider four essential points before deciding upon any extinguishing device: i. The principal effect of the extinguishing agent. 2. The characteristics of the extinguishing agent. 3. The quantity of the extinguishing agent. 4. The method of operating the extinguishing device. These essentials are discussed in detail on the following pages. [ 7 ] How Fire Is Extinguished T here are only two ways to extinguish fire. One by Cooling the burning material down below its burning point, and the other by excluding oxygen from the material so as to Smother the fire. Most extinguishing devices produce both effects, but with one in much greater proportion than the other. The “cooling” method is employed in extinguishing devices whose discharge is principally water, such as soda solutions or calcium chloride solutions. Such solutions produce a “smothering” effect in a lesser degree, but their major function is to extinguish by the cooling or quenching process. Prominent in this class are the Childs soda-acid Extinguishers and Engines, widely used for protection against “ordinary” fires, and the Allweather non- freezing Extinguisher. The “cooling” method is effective on fires in certain kinds of materials and not effective on others (as, for example, oils, greases, etc.). The “smothering” method, however, is effective on fires in practically all kinds of materials including oils, greases, etc. The “smothering” principle, therefore, has a wider application in fire control than the “cooling” principle. There are two types of extinguishing devices which employ the “smothering” principle—one using a free gas and the other a foam. The gas-smothering types (which have a carbon tetrachloride base) produce a heavy free gas which seeks the floor level. They have almost no cooling effect, but their stream is a non-conductor of electricity, making them safe around live high voltage electrical equipment. Because they are compact and do not freeze they are the best available for use on automobiles, motor boats, etc. In this class the Fire-Gun Extinguisher is the most serviceable, depend¬ able and efficient hand fire extinguisher for fighting incipient fires of the classes for which it is recommended. While free gas is effective on fifes under certain conditions, it is not effective under other conditions (as, for example, under condi¬ tions where the free gas cannot retain itself at the necessary con¬ centration at the seat of the fire). The foam principle, as exemplified in *Firefoam , is effective under practically all conditions because it forms an airtight blanket which covers any burning surface, solid or liquid, and puts the fire out and keeps it out and because it does not flow and cannot be carried away from the seat of the fire by drafts, etc. The chemical “bubbles” known as Firefoam , and generated by *Foamite equipment, while principally a smothering substance, *Firefoam and Foamite are the trade-marks registered by Foamite-Childs Corp. [ 8 ] also has a cooling effect, since it is composed of wet foam which absorbs some heat. Firefoam also excludes air (oxygen) long enough to allow the burning material to cool of its own accord. It will be seen from the foregoing that the foam-smothering principle has the most universal application in fire control. And, genuine Foamite Protection as manufactured by the Foamite organization is the pioneer and leader in the foam fire protec¬ tion field. Water as an Extinguishing Agent W ater has always been and will continue to be used most widely for extensive fire fighting, because it is almost uni¬ versally available. But it is not used by itself to any great extent in fire extinguishers or engines. Extinguishing devices em¬ ploying water (or a soda solution) must be placed in a heated cabi¬ net when installed in places subject to freezing temperatures— both to avoid injury to the pressure container and to insure efficient operation. Chemical reactions are sluggish at low tempera¬ tures. Non-freezing extinguishing devices using calcium chloride solution, however, can employ solutions of such concentration that they will withstand temperatures as low as 40 degrees below zero. While extinguishing devices that discharge water or a soda solu¬ tion are effective on ordinary fires, they cannot be properly recom¬ mended for extra-hazardous fires, such as those in oil and paint, or for fires in live high voltage electrical equipment. Water and liquid chemical solutions cannot extinguish and will frequently spread a fire of oil or other inflammable liquid.They are also, to some extent, conductors of electricity. H ow Free Gas Acts T he advantages of the gas-smothering (carbon tetrachloride) type of extinguisher are: Firsts its stream is a non-conductor of electricity and therefore safe on live high voltage electric fires. Second , because of its convenient size and the fact that it has a low freezing temperature, it is adapted to use on automobiles, trucks, motor boats, etc. While this type of extinguishing agent is valuable for the pur¬ poses for which it is intended, it cannot be properly recommended for use elsewhere. The gases, which are heavier than air, seek the floor level, which makes it valueless for overhead fires or fires of large area where the blanket does not completely smother it or may become dislodged or dissipated by drafts of air or the draft of the fire. [ 9 ] What Firefoam Does U ndoubtedly the most useful general extinguishing agent available is Firefoam , generated by Foamite apparatus, since it is effective on both ordinary and extra-hazardous fires. All forms of Foamite Protection (whether portable, stationary or motorized) extinguish and control fire by the “smothering” process, by cutting off the air necessary to combustion with an air-tight, heat-resisting layer of tough, durable Firefoam bubbles containing carbon dioxide gas. These bubbles result from a chemical reaction produced by the mixture of Foamite “A” solution and Foamite “B” solution, the latter employing Firefoam Liquid Stabilizer. The stabilizer gives permanence to the foam and prevents the carbon dioxide gas (generated by mixing the “A” and “B” solutions) from escaping uselessly into the atmosphere. The stream from the portable apparatus with which this blanket is applied to a burning surface is discharged under self-generated pressure and is expanded eight times the volume of the chemical solutions employed. In other words, a Foamite 2 ^-gallon Extin¬ guisher discharges about 20 gallons of Firefoam. Firefoam covers and clings to any burning surface, liquid or solid, vertical or horizontal. It floats on liquids, however volatile (see the illustrations). The draught of the fire will not carry it away; reignition and reflash are impossible. Firefoam insulates surfaces againstfire for alonger time than extinguishing agents that merely wet the surface and run off. It cuts down punishing heat and smoke and gives the operator courage and confidence to stick to his job. It puts fire out and keeps it out. Firefoam has a lesser wet¬ ting effect than cooling agents. It puts the fire out with min¬ imum of damage to property since there is none of the soaking and dripping of water or liquid chemicals. After the fire is out, Firefoam dries and [ 10] A clinging mass of gas-filled bubbles, the Firefoam discharged by Foamite equipment effectively excludes oxygen and smothers fire the instant it is applied to any burning substance. Firefoam puts fire out and keeps it out may be brushed or washed away. It will not injure fabrics which water alone will not damage, and it is not injurious to the skin. While Firefoam should not ordinarily be used around live high voltage electric equipment, a fire in such equipment may reach such proportions that it cannot be put out with the small exting¬ uishers employing a non-conducting liquid. In this event, after the current has been turned of Firefoam is the most effective fire-fight¬ ing weapon that can be used. Although Foamite equipment must be protected against freez¬ ing in places where low temperatures are common, it possesses the obvious advantage of extinguishing both ordinary and extra- hazardous fires, and permits standardization on a single type of equipment. Firefoam is the best available fire protection because of its uni¬ versal application, its maximum fireproofing value, its maximum heat-insulating value, its maximum fire-fighting capacity, and its minimum damage to property. Choosing the Proper Size A very important consideration in choosing extinguishing de¬ vices is the matter of size —by which is meant volume of contents. It is always wise to install the maximum size which the persons who may use the device can carry and operate readily. It may not require the full quantity to put out a fire that is discovered at the very outbreak; but many fires are not detected at once. The standard 2F2-gallon size [ s preferable to smaller sizes—except for automobiles and motor boats where it cannot be conveniently carried, or in the home where the i f^-gallon extinguisher can be more easily operated by a woman or child in an emergency. Unified Method of Operation I t is best to have every piece of fire extinguishing equipment operate in the same manner. This saves time and confusion when fire breaks out. In general, the most satisfactory method is that which requires the operator merely to turn the extinguisher upside down, the rest of the operation being automatic. By this method entire attention can be given to directing the stream, without the wasteful and somewhat strenuous effort of pumping. The pumping method (as employed in the smaller carbon tetra¬ chloride extinguishers) is, however, the only practical method of operating extinguishers for automobiles, motor boats, etc. [n] CHARACTERISTICS Ol TYPE FOAM SC CHEMICALS EMPLOYED Aluminum Sulphate— Bicarbonate of Soda with Foaming Agent Bicart Sul METHOD OF OPERATING INVERT 1 METHOD BY WHICH PRESSURE IS CREATED CHEMICAL REACTION CHEMIC EFFECTIVE RANGE OF STREAM 30 TO 40 FEET 30 T. RATED LIQUID CAPACITY OF MOST COMMON SIZE 2 y 2 GALLONS 234 QUANTITY OF PRINCIPAL EXTINGUISHING AGENT PRODUCED 20 GALLONS 234 NATURE OF PRINCIPAL EXTINGUISHING AGENT FI REFOAM— a mass of bubbles filled with carbon-dioxide gas sc PRINCIPAL EXTINGUISHING EFFECT BLANKETING c IT IS REC¬ OGNIZED AS ADAPTED FOR USE ON Class A Fires Wood, Textiles, Rubbish, Etc. YES BEST AVAILABLE for use in all places involving Class “A” fires because of desirable characteristics not possessed by any other extinguishing agent (fireproofing effect; smaller wetting effect; etc.) Must be kept in heated cabinet when installed in places subject to freezing tem¬ peratures. i for use in places etc. in any way Must be kept 1 installed in plac) peratures. Class B Fires Oils, Greases, Etc. YES BEST AVAILABLE for use in all places involving Class “B” fires because of characteristics not possessed by any other type. because it has c effect. Class C Fires Electrical Machinery Best available where fires have spread be¬ yond the extinguishing capacity of tetra¬ chloride extinguishers and where current is turned off or is of low voltage. The stream is a conductor, but a poor one. except on low caution, or wb be turned off. but a poor on * Class D Fires Pleasure Automobiles, Commercial Trucks, Etc. NO Unless of special splash-proof construction. Must not be exposed to freezing temperature. because of size; to freezing; has effect. UNDERWRITERS’ RATING Al-Bl TRADE NAME OF FOAMITE-CHILDS PRODUCT "FO AMITE” " *The letter "D” is for convenience, no letter having [ i*] FIRE EXTINGUISHERS I-ACID ANTI-FREEZING TETRACHLORIDE ite of Soda ric Acid Calcium Chloride (special grade) Safety Fuse Cartridge Carbon Tetrachloride with important components for depressing freezing point, avoiding corrosion, etc. ERT INVERT PUMP , REACTION BURNING OF SAFETY FUSE PUMPING ACTION 10 FEET 30 TO 40 FEET 20 FEET OR MORE under full pump pressure tLLONS 23^ GALLONS GALLON tLLONS 2 y 2 GALLONS Quantity variable—depends upon amount of liquid which comes in contact with heat of fire. >UID iolution LIQUID calcium chloride solution FREE GAS produced when liquid is vaporized by heat of fire. LING COOLING BLANKETING ES nvolving oils, greases, leated cabinet when ibject to freezing tem- YES for use in places not involving oils, greases, etc., in any way. DOES NOT REQUIRE PROTECTION AT TEMPERATURES DOWN TO 40 DEGREES BELOW ZERO. NO Other types are better adapted for Class “A” fires. This type good only under most favorable conditions because of:—small size; difficulty of confining gas at seat of fire; force, range, and duration of stream not automatically assured; operator cannot devote entire attention to directing stream on fire; must be used with caution in small rooms. fO lically no blanketing NO because it has practically no blanketing effect. YES but foam type is better adapted for Class “B” fires. This type good only under most favorable conditions because of:—small size; difficulty of confining gas at seat of fire; force, range and duration of stream not automatically assured; must be used with caution in small rooms. [0 ige when used with current is likely to earn is a conductor NO except on low voltage when used with caution, or where current is likely to be turned off. Stream is a conductor but a poor one. YES Best available where fires have not spread beyond extinguishing capacity of extin¬ guisher and especially in places where current is not likely to be turned off— because stream is a non-conductor. [0 splash-proof; subject :tically no blanketing NO because of size; not splash-proof; has no blanketing effect. YES BEST AVAILABLE for Class “D” fires because of desirable char¬ acteristics not possessed by any other type. a A1 B2—C2—D1 ILDS” "ALLWEATHER” "FIRE-GUN” n assigned to this class by Underwriters’ Laboratories COPYRIGHT 1924. FO A M ITE-CH 1 LDS CORPORATION [ >3] Protection For Every Emergency T he Foamite organization has designed and manufactured fire extinguishing devices and systems which, each in its prop¬ er place, protect any industry, any plant, any property against any kind of fire. This broad complete coverage of the entire field assures you of getting from Foamite representatives exactly what you need—and nothing else— With Foamite Equipment for ordinary fire risks and for extra-hazardous fire risks such as oil, gasoline, paint, etc.— With Childs Soda-Acid Equipment for protection against ordinary fire risks (not involving oils, greases, etc., in any form)— With the Allweather Equipment for protection against ordinary fire risks (not involving oils, greases, etc., in any form) especially in places where temperatures are apt to be very low (this type, of course, being equally serviceable on the same risks in warm weather)— With the Fire-Gun Equipment for fires in automobiles, motor boats and live electrical equipment. The Foamite representative can provide precisely the type of fire extinguishing equipment that your risks require. He will be glad to analyze problems without cost or obligation to you. The following pages illustrate units of Foamite Protection. [4] ■ TRADE . -■—< • • | Foamite Extinguishers Best Available for Class A and Class B Fires Model CA— 2y 2 Gallons Approved by Underwriters’ Laboratories, Factory Mutuals and U. S. Steamboat Inspection Service T he Foamite Model CA Extinguisher is the original standard foam type extinguisher. As a unit of first- aid protection against both ordinary and extra-hazard¬ ous fires, it has been universally acknowledged to be the “best available” for every type of private, indus¬ trial and institu¬ tional property. Liquid capacity, 2 gallons of solu¬ tions equivalent to a discharge of about 20 gallons of Fire- foam , with an effec¬ tive range of 30 to 35 feet. This is suf¬ ficient to extinguish small fires and hold other fires in check until the arrival of larger apparatus. Same operating characteristics as Model HC, described on page 16. Regularly finished in highly polished copper. Sold com¬ plete with hanging bracket, charge, recharge record tag, and directions for charging and maintenance. Model DC—5 Gallons Approved by Underwriters’ Laboratories T he Foamite DC Extinguisher is the largest capacity hand extinguisher that can be satis¬ factorily handled by one man. It is recommended for the protection of those industrial risks where the nature of the hazard dictates a preference for a 5-gallon unit in the hands of a single operator, rather than two 2jT-gallon units separately oper¬ ated. It is also favored on risks not extensive enough to require a Foamite 40-gallon Engine. The Foamite DC discharges about 40 gallons of Firefoam at an effective range of 30 to 35 feet in practically the same time required for one Foamite CA 2f^-gallon Extinguisher to discharge about 20 gallons of Firefoam. In fire fighting, time is such an important factor that the rapidity with which the larger quantity of extinguishing agent can be applied, and the ability of one oper¬ ator to do it alone with a single device, explain the popularity of Model DC. Finished in red. Strong webbing shoulder strap is fitted with trigger snap fasteners. Sold complete with charge, recharge record tag, and directions for charging and maintenance. Model CA Model DC [ v] Model HC T TRADE # -w~~i • • 1 roamite Extinguishers MARK Best Available for Class A and Class B Fires (See pages 5, 10, 12) Model HC— iy 4 Gallons 1 he Foamite Model HC Extinguisher is ideally suited for home protection. Its size, weight and simplicity of operation make it a practical device for use by women or children. Capacity is sufficient for the first-aid requirements of most households. The handsome statuary bronze finish harmonizes with the furnishings of the finest home. Sturdy yet simple construction in¬ sures its dependable operation in an emergency. When charged, the inner container holds Foamite “A” Solution and the “B” Solution is in the outer shell. Upon discovering an incipient fire, simply lift the extinguisher from its bracket, carry it by the ring- cap to the fire, and turn it upside down. This releases the loose stopple sealing the inner container, and permits the two chemical solutions to mix and expand eight times their volume into Fire- foam (see page io). The stream of this unique foam, equally effective on ordinary and extra-hazardous fires, is forced out of the nozzle by pressure developed within the extinguisher by the mixing of the two solutions. All Foamite Portable Hand Extinguishers are operated in the same simple manner. Liquid capacity of Model HC, gallons of solutions, equivalent to a discharge of about io gallons of Firefoam , with a range of 25 to 30 feet. Sold complete with hanging bracket, charge, recharge record tag, and directions for charging and maintenance. Model FD— 2% Gallons (Splash Proof) T he Foamite Model FD Extinguisher is designed for municipal fire departments, but it has been suc¬ cessfully used in many properties, like mines, where conditions call for a device that can be carried to a fire in other than a vertical position, and that will not func¬ tion prematurely by accidental mixture of solutions. This is a sealed-stopple, splashproof extinguisher, having the same solution capacity (2^2 gallons) and operating characteristics as the Foamite Model CA. In the construction, however, the wheel cap design is varied to provide, in the FD, a valve stem by which the stopple sealing the inner tube (“A” solution) may be raised, for operating, or lowered, to prevent mixture of solutions during carriage on running board of car or fireman’s back. Nozzle is provided with shut-off valve. Heavy leather carrying straps hold the extinguisher right side up or inverted, as desired, permitting free use of both hands. To operate, simply open the stopple valve in cap and invert the extinguisher. Finished in polished copper or nickel plate. Sold complete with charge, recharge record tag, and directions for charging and maintenance. [16] Model FD Foamite Foam Generator MARK A Scientific Practical "Second-line De¬ fense” Backing Up First-aid Equipment T he Foamite Foam Generator produces a sustained stream of fire-smothering Firefoam by introducing a dry chemical powder into a flowing stream of water — thus eliminating the expense and bulk weight of pre-mixed solutions necessary to other forms of chemical fire-fighting equip¬ ment. It is designed to back up the smaller but necessary “first-aid” Foamite equipment, which can be put into instant service immediately upon detection of a fire, with a larger-sized stream of Firefoam , the supply of which is only limited by the availability of water and Foamite Generator Powder. The Foamite Foam Generator gives industrial plants what they have long wantedfor fighting advanced fires that water alone may not control—fires re¬ sulting from the ever-increasing use of inflammable liquids in industry— fires involving lacquer, j apan, enamel, asphalt, varnish, oils, gasoline, rubber solvents, etc. It is also designed for fighting advanced fires in ordinary risks. It is extremely easy to operate. Its lightness and compactness permit its being carried by one man and all that is necessary is to connect it into a hose line leading from a hydrant or other source of water supply and attach ioo feet or 150 feet of 23/2-inch rubber lined hose with 1 24 -inch nozzle tip to the outlet connec¬ tion on the Generator. The shut-off valve on the inlet side of the Generator is opened and the hopper kept filled with the Foamite Generator Powder. The rate of flow of water through the Generator automatically controls the drawing into the stream of the right amount of powder. Should the flow of water fluctuate, the flow of powder will fluctuate proportionately. As long as water is turned on, and the hopper kept filled, the Generator will deliver its stream of Firefoam. The reserve stock of Powder and availability of water are obviously the only limits to the quantity of Firefoam which can be available for use on a fire. The Foamite Foam Generator is recommended for use in large industrial plants using inflammable liquids such as paint and varnish factories, dry cleaning plants, manufacturing plants using dip tank processes, coke-by-product plants, etc. It has also proved especially valuable in fighting ordinary fires since it avoids water damage and absorbs heat and reduces smoke. Foamite Engineers have also designed a generator to meet the special needs of fire department service—the Model 17. The unit is so designed that it can easily be carried in a metal carrying case that can be mounted on the running board or any other readily accessible position on the apparatus. The Model 17 is nickel plated finish; the carrying case, fire department red. Model 15, for Industrial Service ■ 1 ^ TRADE # • roamite hngmes MARK ^ Best Available for Class A and Class B Fires (See pages 5, 10, 12) Model FM Metered Type — 40 Gallons Approved by Underwriters’ Laboratories and Factory Mutuals T he Foamite Metered Type Engine marks another great advance by Foamite Engineers in the science of fire protection. The interior of this engine is designed to mix the two chemical solutions in measured or me¬ tered quantities, as in the large Foamite Pumping System. This produces a quantity and quality of Firejoam having extinguishing value never before ap¬ proached in a portable foam engine of this size. The Model FM has narrow tread and short handles for factory, garage or other indoor use, its width over all being 30 inches. As shown below, the Foam¬ ite “A” Solution is contained in a removable inner tube, sealed by stopple and valve in cap to prevent mixing of the “A” and “B” Solutions until the engine is operated. To use on a fire, simply open this valve and tip the engine over. Nozzle has control valve. The engine holds approximately 40 gallons of solutions, and it discharges about 300 gallons of Firejoam at an ef¬ fective range of about 60 feet. The dis¬ charge continues long enough to enable the operator to extinguish a large area of burning surface. The Foamite Model FM Engine and the Model DM, illustrated on page 19, were the first foam type engines to be approved and labeled by Underwriters’ Laboratories. Foam Type Engines are the only chemical fire-fighting engines having this approval for both Class A and Class B fires. Model FM Foamit e Engine with narrow tread for indoor use, showing removable inner tube and stop¬ ple in cap. Finished in red. Sold complete with charge, recharge rec¬ ord tag, and direc¬ tions for charging and maintenance. 1 "N TRADE # -y-^ • Eoamite Engines MARK Best Available For Class A and Class B Fires (See pages 5, 10, 12) Model DM Metered Type — 40 Gallons Approved by Underwriters’ Laboratories and Factory Mutuals institutions, etc. Long handles and pull rope are also provided on this model, which is 46 inches wide over all. ALL Foamite Chemical En¬ gines (see also page 22) are equipped with steel wheels, for severe service. T he Foamite Model DM Metered Type Engine is the same as the Model FM described on page 18, except that the 40-gallon solution tank is mounted on a wheel carriage of heavier con¬ struction,with wide tread for outdoor service around factories, private estates, Co] Foamite Automatic Protection for MARK Special Hazards A lmost every modern factory employs dipping, quenching, or spraying oper- . ations using inflammable liquids under conditions that present an extra- hazardous fire risk and require special, technical consideration if safety is to be obtained. Ordinary installations of extinguishing equipment won’t do. Some of the inflammables associated with these speeding-up industrial pro¬ cesses are lacquer, japan, enamel, asphalt, varnish, oil, gasoline, and rubber solvents. The tanks or kettles containing them are important links in the manu¬ facturing process, and the inevitable fire, once beyond local control, can do no end of direct damage and in addition cripple the whole plant and halt production all down the line. Fires in such risks flash quickly and burn furiously over the entire surface of the inflammable liquid exposed. Water cannot be used to extinguish them (see page io). They must be smothered out with Foamite Protection, and with the greatest possible speed—faster, indeed, than it is possible to operate extinguishers manually. All forms of Foamite Automatic Protection are operated automatically by quick-operating heat-actuated releasing mechanisms known as theLowe Release. To cope with this problem, Foamite Engineers have developed several successful methods of applying Foamite Protection ( Firefoam ) automatically. Each operates so rapidly that all fire is extinguished before it has gained any headway in the dip tank and before it can possibly spread to overhead construction. Principles of these several methods are described in detail in an illustrated booklet called “Dipping Dangers ” which will be mailed free on request. The Automatic Foamite Engine System T he Automatic Foamite Engine System consists of a sufficient number of Foamite Model F2-S 40-gallon Engines to generate enough Firefoam to extinguish the worst fire that can occur in the risk which it is intended to protect. These engines are linked together and held from tipping by the releasing mechan¬ ism. The heat from a fire causes the releasing mechanism to trip the bank of Foamite Engines. An arrangement of piping and distributors for the application of the Firefoam completes the mechanical set-up of the System. Each Model F2-S Foamite Engine discharges about 300 gallons of Firefoam. The Foamite Engine System, with front side of cage removed; the entire unit being ready for operation. [20] Automatic Foamite Model RT Extinguisher MARK V— Approved by Underwriters’ Laboratories and Factory Mutuals M any risks are not large enough to require as much protection as is supplied by an Automatic Foamite En¬ gine System or to warrant the cost of providing such an excess of safety. Others do not require the distribution of foam over the hazardous area by means of pressure. For these risks, the Foamite Model RT Extinguisher, having 12 gal¬ lons solution capacity and a discharge of about 100 gallons of Firefoam , is the ideal protective device. The RT Extinguisher is suspended directly over the fire hazard. A fire causes a rapid and sudden rise of temperature which sets off the sensitive automatic releasing mechanism. The “tumbler” rotates freely and discharges fire-smooth- ering Firefoam on the burning material. This unit proves its value in putting out the comparatively small inflammable liquid fires before they can spread. Automatic Foamite Extinguisher System Models DC-1 and DC-2 T hese Automatic Foamite Extin¬ guisher Systems are, in effect, minia¬ ture engine systems and are designed to protect dip tanks and drain boards too small to warrant installing an engine sys¬ tem, or dip tanks which are closed, or dip tanks over which the Foamite Model RT Extinguisher cannot be hung. The discharge of Firefoam into the dip tank and over the drain board is accom¬ plished through an arrangement of pip¬ ing and flared nozzles and deflector nozzles. These nozzles are designed to discharge a form of foam stream known to operate most efficiently on burning in- flammableliquids. TheDC-i Extinguish¬ er unit discharges about 40 gallons of Firefoam and the DC-2 about 80 gallons. Illustration at left shows the DC-2 sus¬ pended from the ceiling in an industrial property. "CHILDS” Soda-Acid Extinguishers and Engines 2% Gallon Extinguisher (left) Approved by Underwriters’ Laboratories, Factory Mutuals and U.S. Steamboat Inspection Service A loose-stopple extinguisher operated in the simple, tip-over manner—the standard first- aid device of its kind. Finished in polished copper or red. No. 6A—2^2 Gallons (above, right) A widely used splashproof model designed for fire department service. Special acid-seal¬ ing device prevents premature mixing of acid and soda solution. To operate, simply open valve in cap and invert the extinguisher. Finished in polished copper or nickel plate. Model FU-1 Engine — 40 Gallons Standard for 29 years For Class A Fires (See pages 5, 10, 12) Special circu¬ lars describing these Childs E xtinguishers and Engines more folly will be sent on re¬ quest. Model DU-1 For indoor use where a larger soda-acid unit than the Childs 2,14-gallon Extinguisher is desired for protection against ordinary haz¬ ards. Model FU-i is a sealed-stopple engine; Model CU-i Engine (not illustrated) is the same except that it has a loose stopple. Width over all, 30 inches. Finished in red. Model DU-1 Engine — 40 Gallons Has the same sealed-stopple tank as FU-i Engine, but is better adapted to outdoor ser¬ vice; 46 inches wide over all, and equipped with long handles and rope reel. Finished in red. The above engines are approved by Underwriters' Laboratories and Factory Mutuals. Model KU Engine — 20 Gallons An intermediate size loose-stopple engine for indoor use. Width over all, 21 inches. Finished in red. Approved by Underwriters’ Laboratories. Model GU-1 Engine — 40 Gallons (Not illustrated ) A Horizontal Type Engine specially de¬ signed for protecting villages, country estates and large factory yards. Has a wide tread, long handles, pull rope reel, and gong. Approved by Underwriters’ Laboratories. Model KU Model FU-1 [»] Fire-Gun Carbon Tetrachloride Extinguishers For Class C and Class D Fires T he Fire-Gun Extinguisher employing Fire-Gun Fluid fills the need for a de¬ pendable first-aid device that is light in weight, of small size, and easily operated, yet powerful against fires of the classes for which it is recom¬ mended. These extinguishers are made in four sizes: Model No. o—i Quart Model No. i—Quart Model No. 2 —\]/2 Quart Model No. 4—i Gallon I qt. ij 'A qt- The Models No. o, No. i and No. i are especially adapted for use on automo¬ biles, motor-boats, air-craft, railway trains, and live electric equipment of high voltage. They are operated manually by a double-acting pump delivering the entire liquid contents in a continuous stream of over 25 feet with fewer strokes and less effort than is required with other extinguishers of this type. They are finished in either polished brass, red, or red with nickel trim, as specified. Note: Tetrachloride units do not have to be recharged annually. However, periodic inspections should be made to assure that the units are always fully charged and in operative condition. Note: Because tetrachloride extinguishers have no Class “A” rating they are not recommended for general or for home fire protection. Model No. 4—1 Gallon Fire-GunNo. 4—One gallon (Stored pressure type) T he Fire-Gun Model No. 4 was especiallydesigned for use on fires in electric power generating sta¬ tions and at various control points in electrical sys¬ tems. It is valuable not only for the utilities but for all industries where protection with large units employ¬ ing non-conducting extinguishing fluid is needed. It is of the stored pressure type. Operates immediately with one easy pull on a lever. Will operate from any position. Stream may be turned on and off at will. Hangs flat against the wall, taking up but minimum of space. Wherever a man can walk, climb, or crawl, this extinguisher can be taken and operated. Positive in action as only 55 of the 100 pounds are necessary to discharge the entire load with a steady pressure for maximum stream. Finished in red. Fire-Gun Fluid is non-freezing at 50 degrees below zero, is a non-conductor of electricity and is free from impurities. Trade "ALLWEATHER” Mark Non-Freezing Extinguisher For Class A Fires (See pages 5, 10, 12) Approved by Underwriters’ Laboratories Wi ater hydrants, buckets and tanks often freeze up solid in cold weather. The chemical solutions of most gallon fire extinguishers are also subject to freezing, and the chemical reactions by which they are discharged become nota¬ bly sluggish as the temperature approaches 32 degrees F. On many outdoor and unheated indoor risks, no first-aid device offers more satisfactory protection against Class A fires than the Allweather. The 'lyi. gallons of calcium chloride solution held by the Allweather are discharged automatically by a pressure-gen¬ erating device when the extinguisher is inverted. No pumping required. Stream has range of 30 to 40 feet. Operating method is positive and dependable under all weather conditions, even at 40 degrees below zero. This extinguisher, of course, is equally serviceable on the same risks in warm weather. Caution: The Fire-Gun, Allweather and Childs Hand Pump Extinguishers are the only types of first-aid fire protec¬ tion devices that do not need protection against freezing. DO NOT ATTEMPT to depress the freezing point of other types of extinguishers by adding so-called non-freezing compounds. Such action will be detrimental to the efficient operation of the units. Send for free book¬ let, “Protection of Fire Extinguishers Against Freezing." Model A 2y£-gallons capacity Red finish "CHILDS” 5-Gallon Non-Freezing Hand-Pump Fire Extinguisher For Class A Fires Approved by Underwriters’ Laboratories I ike the Allweather Extinguisher, the Childs j Hand-Pump Fire Extinguisher is recommended for use in all unheated properties, as cold storage plants, stock yards, lumber camps and yards, freight houses and yards, bridges and dry docks, coal yards, warehouses, and the like. This extinguisher is brought into action by manually operating the pump with one hand and directing the stream with the other by the flexible hose connecting the nozzle to the pump. The double-acting pump throws a powerful, steady stream a distance of about 30 feet. The supply of water or non-freezing solution can be renewed during operation, providing a continuous stream and eliminating the delay in recharging. Hand-Pump 5-Gallons Capacity Red finish “““ “SiK Foamite-Childs Protection A Complete Engineering Service ^Against Fire Foamite-Childs Corporation Fire Protection Engineers and Manufacturers General Offices and Factory, Turner Street, Utica, N.Y. Foamite-Childs of Canada, Ltd., Toronto, Ont. OFFICES IN FOLLOWING CITIES ATLANTA, GA. BOSTON, MASS. CHICAGO, ILL. CLEVELAND, OHIO DENVER, COLO. DETROIT, MICH. EL PASO, TEXAS JACKSONVILLE, FLA. KANSAS CITY, MO. LOS ANGELES, CALIF. NEW ORLEANS, LA. NEW YORK, N.Y. OMAHA, NEB. PHILADELPHIA, PA. PITTSBURGH, PA. TORONTO, ONT., CANADA MONTREAL, QUE., CANADA Sales and Engineering Representatives in the Leading Cities of All Countries Outline your fire protection needs on the Request Card or in a letter today, while you have something to protect. Every day the newspapers report destructive fires that were not expected. Free Literature T his booklet describes several units of Foamite Protection. Other units are described in special literature which will be sent free on request: "Dipping Dangers ”—A treatise on the latest scientific methods of fire prevention and protection for modern industrial hazards, featuring Automatic Foamite Protection. "Industrial Fire Chief ” —Bi-monthly magazine published in the interest of Fire Protection. “Foamite Foam Generator”— Folders of industrial type and fire department type. "Protection of Extinguishers Against Freezing ”—A folder of cold weather facts. "A Plain Statement of Facts About Foam Fire-Fighting Equipment ”—Questions and answers about Firefoam Liquid Stabilizer and the Foamite System, with special reference to the oil industry. "Yesterday a Home” —A folder of particular interest to home owners. "What Is My Home Worth” —A record for keeping a complete inventory of your personal property. FVintir*g^P»|>*r* August 1927 IN 0. s. *• H.W. COGGESHALL, ‘Printing UTICA, N.Y. MM CORRECT PROTECTION against